CARACTERÍSTICAS
Temperature range: operating 100c -- 400c
Humidity: operating : 20%-95%, non-operating : 10%-95%
Remarks: 85% in normal condition and 95% with special coating process
Hold up time: 1.6 ms minimum at full load & nominal input voltage
Dielectric withstand: input / output 1500 vac for 1 second
Input to frame ground 1500 vac for 1 second
Efficiency: 65% typical, at full load
Power good signal: on delay 100 ms to 500 ms, off delay 1 ms
Over load protection: 130 ± 20%
Over voltage protection: +5v → 5.5v ~ 7.0v, + 3.3v → 4.0v ~ 4.5v .
Short circuit: 5v,12v,3.3v
Mi noise filter: FCC class A, CIPR22 class A
Safety: UL 1950, CSA 22.2 no/ 950, IEC 950
Remote on / off control
The unit shall accept a logic open collector level which will Disable / Enable all the output voltage (exclude +5v standby), as logic level is low, outputs voltage were enable; as logic level is high, outputs voltage were disabed
Cooling: two 40 mm dc fans (module)
AC inlet in each module
|